北京市大西洋仪器工程有限责任公司

 WAVE RUNNER6200/6100/6050/6051/6030 示波器
  • WAVE RUNNER6200/6100/6050/6051/6030 示波器
  • WAVE RUNNER6200/6100/6050/6051/6030 示波器

    参考价格: ¥0.00
    产品型号:WAVERUNNER6200/6100/6050/6051/6030
    所在地区:北京
    上架时间:2012年09月05日
    留言咨询
    与企业取得联系时请告知该信息获取自中国教育装备采购网
    我要分享
    详细说明

    Leading Features

    • 350 MHz, 500 MHz, 1 MHz and 2 MHz Bandwidths
    • Up to 10GS/s Sample Rate
    • 1 Mpts on All Channels, Expandable to 12/24 Mpts
    • Compact and Lightweight
    • Easy User Interface
    • New 2.5 mm Passive Probe
    • Touch Screen Interface
    • Vertical Controls for Each Channel
    • USB 2.0 and 802.3xx LAN Ports
    • Open Windows 2000

    Excellent Performance, Great Price, Easy to Use
    LeCroy抯 WaveRunner?/sup> 6000 Series is built to be the world抯 best everyday bench oscilloscope. It offers the best acquisition specifications, a user interface that makes it easy to perform the most common oscilloscope functions, industry-leading long term support and a "feel" that makes
    the oscilloscope a pleasure to drive.

    For the first time, LeCroy has combined the type of high performance front amplifier, ADC, memory and triggering used in more expensive oscilloscopes and designed it all into a very affordable package. The WaveRunner 6000 Series also introduces a user interface that makes viewing and measuring signals simple and fast.

    With the WaveRunner 6000 Series, all viewing controls and basic oscilloscope functions are easily at hand using front panel knobs. You get fast views and can zoom in to see details on the bright touch panel color screen. Or use the simple and intuitive controls to call up exactly the measurements you need.

    The WaveRunner 6000 Series includes an industry-leading signal acquisition path, which provides a 5 GS/s ADC on every channel (Model 6050 and above) and 1 Mbyte of standard memory. No need to worry about the undersampling or aliasing caused by slower ADCs or shorter memories on other oscilloscopes.

    The WaveRunner 6000 Series comes standard with the new PP007 500 MHz passive probe (one per channel). This 2.5 mm high impedance probe offers excellent characteristics for probing everyday signals. LeCroy also offers a wide range of optional single-ended and differential active probes, current probes, optical to electrical (O/E) converters and differential amplifiers.

    Lastly, we decided to architect the oscilloscope so that users could add just the functionality they want. There are options for testing power devices, serial data mask testing, jitter and timing analysis, and for a wide variety of probes, O/E converters and other application specific devices.

    Altogether, the WaveRunner 6000 Series sets a new industry standard for high performance at low price in everyday bench oscilloscopes.

    WaveRunner Specifications

    Vertical System 

    WR 6030 WR 6050 WR 6051 WR 6100 WR 6200
    Nominal Analog Bandwidth @ 50Ω (-3 dB) 350 MHz 500 MHz 500 MHz 1 GHz 2 GHz
    Rise Time (Typical) 1 ns  750 ps  750 ps  400 ps 255 ps
    Input Channels 4 4 2 4 4
    Bandwidth Limiters 25 MHz; 200 MHz
    Input Impedance  1MΩ||<20pF (10 MΩ || 9.5pF using PP007 probe)
    Input Coupling  50Ω:DC, 1MΩ:AC, DC, GND
    Maximum Input Voltage 50 Ω:5 V rms, 1MΩ:250 V max (DC+Peak AC(DC-10 kHz))
    Channel-Channel Isolation > 40dB @ <100MHz (3dB @ full bandwidth)
    Vertical Resolution 8 bits; up to 11 bits with enhanced resolution (ERES) 
    Sensitivity  
    DC Gain Accuracy ?.0 % of Full Scale (typical); ?/font>1.5% full scale (warranted)
    Offset Range 50Ω:?00 mV @2-4.95 mV/div, ?1 V @ 5-100 mV/div,
      ? 10 V @ 102mV - 1 V/div
    1MΩ:?00 mV @2-4.95 mV/div, ?1 V @ 5-100 mV/div,
    ?10 V @ 102mV - 1 V/div, ?100 V @ 1.02-10 V/div
    Offset Accuracy ?1.5 % + 0.5 % of offset value + 1 mV)
    Probing System BNC or ProBus
    Horizontal System
    Timebases  Internal timebase common to all input channels; an external clock may be applied at the Auxiliary Input
    Time/Division Range  Real Time: 200 ps/div - 10 s/div, RIS mode: to 20ps, Roll mode: up to 1000 s/div
    Clock Accuracy  ? 5 ppm @ 25oc (? 10ppm @ 5-40oC)
    Jitter Noise Floor  2 ps rms (Typical)
    Time Interval Accuracy  Clock Accuracy + Jitter Noise Floor
    Sample Rate + Delay Time Accuracy  Equal to Clock Accuracy
    Trigger & Interpolator Jitter (RMS) ≤ 3 ps rms (Typical)
    Channel- Channel Deskew Range ? 9x time/div setting, 100 ms max, each channel
    External Sample Clock DC to 1 GHz; 50Ω or 1MΩ BNC input
    Roll Mode Minimum rise time and amplitude requirements apply at low frequencies. (User selectable. Available at slower time/div settings)
    Acquisition System
      WR 6030 WR 6050 WR 6051 WR 6100 WR 6200
    Single-Shot Sample Rate/Ch 2.5 GS/s 5 GS/s 5 GS/s 5 GS/s 5 GS/s
    Interleaved Sample Rate (2Ch) 5 GS/s N/A N/A 10 GS/s 10 GS/s
    Max. Random Interleaved Sampling (RIS) Rate <<<    200 GS/s    >>>
    Max. Trigger Rate  125,000 waveforms/second
    Sequence Time Stamp Resolution 1 ns
    Minimum Time Between Sequential Segments 8 祍
    Acquisition Memory
     Standard
    Max. acquisition points (4 Ch/2 Ch; 2Ch/1 Ch in 6051)
    2M (1Ch) 
      Option S     2M / 4M    
      Option M     4M / 8M    
      Option L     8M / 16M    
      Option VL     12M / 24M    
    Acquisition Processing 
    Time Resolution (min. Single-shot)  200 ps (5 GS/s) for WR6030, WR6050 and WR6051;
    100 ps (10GS/s) for WR6100 and WR6200
    Averaging  Summed and Continuous Averaging to 1 million sweeps
    Enhanced Resolution (ERES)  From 8.5 to 11 bits vertical resolution
    Envelope (Extrema)  Envelope, floor or roof for up to 1 million sweeps
    Interpolation  Linear, Sin/x
     
    Triggering System 
    Trigger Modes  Normal, Auto, Single, and Stop
    Sources  Any input channel, External, Ext/10, or line; slope and level unique to each source
    Trigger Coupling  DC
    Pre-trigger Delay  0 ? 100% of memory size (adjustable in 1% increments, or 100 ns)
    Post-trigger Delay  10,000 divisions in real time mode, limited at slower time/div settings in roll mode)
    Hold-off  2 ns to 20 s or 1 to 99,999,999 events
    Internal Trigger Level Range  ?.1 div from center
    Max Trigger Frequency
    Trigger Sensitivity with edge trigger (CH1-4+external) 
    For WR6030 2 div at < 350 MHz
    1 div at < 250 MHz 
    For WR6050 &
    WR 6051
    2 div at < 500 MHz
    1 div at < 350 MHz
    For WR6100 2 div at < 1 GHz
    1 div at < 750 MHz
    For WR6200 2 div at < 2 GHz
    1 div at < 1.8 GHz
    Trigger Sensitivity with Smart trigger (CH1-4+external) 
    For WR6030 350 MHz Max
    @ ≥ 10 mV 
    For WR6050 &
    WR 6051
    500 MHz Max
    @ ≥ 10 mV 
    For WR6100 750 MHz Max
    @ ≥ 10 mV 
    For WR6200 750 MHz Max
    @ ≥ 10 mV 
    Trigger Level DC Accuracy  ?4% full scale ? 2 mV (typical)
    External Trigger Range  EXT/10 ? 4V; EXT ?400mV
     
    Basic Triggers 
    Edge/Slope/Line  Triggers when signal meets slope (positive or negative) and level condition. 
     
    SMART Triggers 
    State or Edge Qualified  Triggers on any input source only if a defined state or edge occurred on another input source. Delay
    between sources is selectable by time or events. 
    Dropout Triggers if signal drops out for longer than selected time between 2 ns and 20 s.
    Pattern  Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input, 2 channels and external trigger input (6051))
    Each source can be high, low, or don抰 care. The High and Low level can be selected independently.
    Triggers at start or end of the pattern.
     
    SMART Triggers?with Exclusion Technology 
    Glitch & Pulse Width Triggers on positive or negative glitches with widths selectable from 600 ps to 20 s or on intermittent faults.
    Signal or Pattern Interval  Triggers on intervals selectable from 2 ns to 20 s.
    Timeout (State/Edge Qualified) Triggers on a source if a given state (or transition edge) has occurred on another source. Delay between sources is 10ns to 20 s, or 1 to 99,999,999 events.
    Exclusion Triggering  Trigger on intermittent faults by specifying the normal width period.
     
    Automatic Setup 
    Auto Setup  Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals. 
    Vertical Find Scale  Automatically sets the vertical sensitivity and offset for the selected channels to display a waveform with maximum dynamic range.
     
    Probes 
    Probes  One PP007 per channel standard; Optional passive and active probes are available. 
    Probe System: 
    ProLink with ProBus
    Automatically detects and supports a variety of compatible probes.
    Scale Factors  Automatically or manually selected depending on probe used.
     
    Color Waveform Display
    Type  Color 8.4" flat-panel TFT-LCD with high resolution touch screen
    Resolution  SVGA; 800 x 600 pixels
    Realtime Clock  Dates, hours, minutes, seconds displayed with waveform. Accurate to ? 50 ppm. SNTP support to synchronize to precision internet clocks.
    Number of Traces  Display a maximum of 8 traces. Simultaneously display channel, zoom, memory, and math traces.
    Grid Styles  Auto, Single, Dual, Quad, Octal, XY, Single + XY, Dual + XY
    Waveform Styles  Sample dots joined or dots only
     
    Analog Persistence Display
    Analog & Color-Graded Persistence  Variable saturation levels; stores each trace抯 persistence data in memory
    Persistence Selections  Select analog, color or three dimensional
    Trace Selection  Activate Persistence on all or any combination of traces
    Persistence   Aging Time Select from 500 ms to infinity
    Sweeps Displayed  All accumulated, or all accumulated with last trace highlighted
     
    Zoom Expansion Traces
    Display up to 4 Math/Zoom traces
     
    CPU
    Processor  Intel Celeron 1.7 GHz or better
    Processing Memory  256 MB on Std, S & M option; 512 MB with L and VL option
    Operating System  Microsoft Windows 2000 Professional
     
    Internal Waveform Memory
    M1, M2, M3, M4 Internal Waveform Memory (Store full-length waveforms with 16 bits/data point) or store to any number of files limited only by data storage media.
     
    Setup Storage
    Front Panel and Instrument Status  Save to the internal hard drive, over the network, or to a USB connected peripheral device.
     
    Interface
    Remote Control  Via Windows automation, or via LeCroy Remote Command Set.
    GPIB Port (Optional)  Supports IEEE ?488.2
    Ethernet Port  10/100Base-T Ethernet interface (RJ-45 connector)
    USB Ports  5 USB 2.0 ports (one on front of instrument) support Windows compatible devices
    External Monitor Port Standard Standard 15-pin D-Type SVGA-compatible DV-15; connect a second monitor to use dual-monitor display mode.
    Parallel Port  1 standard DB-25
    Serial Port  DB-9 RS-232 port (not for remote oscilloscope control)
     
    Auxiliary Output
    Signal Types  Select from calibrator or control signals output on front panel
    Calibrator Signal 5 Hz ? 5 MHz square wave or DC Level; 
    0.0 to +0.5 Volts into 50 Ω (0 - 1 V into 1 MΩ ), or TTL Volts (selectable)
    Control Signals  Trigger enabled, trigger out, pass/fail status 
     
    Auxiliary Input
    Signal Types  Select from External Trigger or External Clock input on front panel
     
    General 
    Auto Calibration  Ensures specified DC and timing accuracy is maintained for 1 year minimum
    Power   100?40 Vrms at 50/60Hz; 100-120 Vmrs @ 400 Hz; Installation category: 300 V CAT ||; Max. Power Consumption: 400VA/400W; 350VA/350W (for WR6030 and WR6051 only)
     

    Environmental

    Temperature (Operating) +5 ℃ to +40 ℃
    Temperature (Non-Operating) ?0 ℃ to +60 ℃
    Humidity (Operating) 5% to 80% relative humidity (non-condensing) up to 30 ℃. Upper limit derates linearly to 45% relative humidity (non-condensing) at +40 ℃.
    Humidity (Non-Operating) 5% to 95% relative humidity (non-condensing) as tested per MIL朠RF?8800F.
    Altitude (Operating) 3048 m (10,000 ft) max at up to 25℃, derates to 610m (2,000 ft) at 40℃
    Altitude (Non-Operating) 12,190 m (40,000 ft) 
     
    Physical Dimensions
    Dimensions (HWD)  211 mm x 355 mm x 365 mm (excludes feet) 8.3" x 13.8" x 14.3" 
    Net Weight  10 kg (22 lbs), excluding printer
    Shipping Weight  less than 13.6 kg (30 lbs)
     
    Certifications
    CE Approved, UL and cUL listed; conforms to EN 61326-1, EN61010-1, UL 3111-1, and CSA C222 N0. 1010.1
     
    Warranty and Service
    3-year warranty; calibration recommended annually. 
    Optional service programs include extended warranty, upgrades and calibration services. 
     
    WaveRunner 4- Channel Digital Oscilloscope Product Code
       
    2 GHz, 5 GS/s-1 Mpts/4 ch; 10 GS/s-2Mpts/2ch,? ch Color DSO WR 6200

    1 GHz, 5 GS/s-1Mpts/4 ch; 10 GS/s-2 Mpts/2ch,? ch Color燚SO  WR 6100

    500 MHz, 5 GS/s-1 Mpts/4ch; 5 GS/s 2 Mpt/2ch, 4 Ch Color燚SO  WR 6050

    500 MHz, 5 GS/s-1 Mpts/2ch; 5 GS/s-2 Mpts/1ch,? Ch Color DSO    WR 6051

    350 MHz, 2.5 GS/s, 1 Mpts/4 ch; 5 GS/s, 2 Mpts/2 ch,?-Ch Color燚SO WR 6030
       
    Included with Standard Configuration
    10:1 10 MΩ, 500 MHz BW Passive Probes - Qty 4 
    (2 with WaveRunner 6051) 
    PP007-WR-1
    Operator抯 Manual, Remote Control Manual, and Utility software and Recovery Software on CD-ROM  
    Printed Getting Started Manual  
    Optical 3 button Wheel Mouse-USB  
    Standard Ports; 10/100Base-T Ethernet, USB (5), Parallel, RS-232, SVGA Video Output, Audio input/output  
    Internal Hard Drive  
    Protective Front Cover  
    Standard Commercial Calibration and Performance Certificate  
    Three-Year Warranty  

     

    Memory Options   
    2 Mpts/Ch, 4 Mpts/Ch using 2 Ch (1 Ch for 6051)    WR6-S
    4 Mpts/Ch, 8 Mpts/Ch using 2 Ch (1 Ch for 6051)    WR6-M
    8 Mpts/Ch, 16 Mpts/Ch using 2 Ch (1 Ch for 6051)    WR6-L 
    12 Mpts/Ch, 24 Mpts/Ch using 2 Ch (1 Ch for 6051)    WR6-VL
    ??
    Hardware Options  
    GPIB Interface  WR6-GPIB
    Removable HDD WR6-RHD
    CD-RW Upgrade WR6-CDRW
    ?
    WaveShape Analysis Packages  
    Jitter and Timing Analysis WR6-JTA2
    PowerMeasure Analysis WR6-PMA2
    Digital Filter Package WR6-DFP2
    Serial Data Mask Package WR6-SDM
    Ethernet Test Package 
    (WaveRunner 6100 and 6200 Only1)
    WR6-ENET
    USB 2.0 Compliance Software
    (WaveRunner 6200 Only2
    WR6-USB2
    Advanced Math Package WR6-XMATH
    Intermediate Math Package XWAV
    Value Analysis Package (XWAV + JTA2) WR6-XVAP
    Developers Customization Kit WR6-XDEV
    Norton Antivirus WR6-AV
    Master Analysis Package (XMATH + XDEV + JTA2) WR6-XMAP
     
    1
    Package may be used with lower BW oscilloscope models, however some measurements will not operate with signals at all data rates.

    <2 Can be used with lower BW oscilloscope models, however only USB 1.1 test functions will be available. WaveRunner 6200 required for USB 2.0 capacity.

    Selected Accessories   
    500 MHz Passive Probe  PP007-1
    2.5 GHz Active Voltage Probe  HFP 2500
    1.5 GHz Active Voltage Probe  HFP 1500
    1 GHz Active Voltage Probe  HFP 1000
    1.0 GHz Differential Probe  AP034
    500 MHz Differential Probe  AP033
    30A, 50 MHz Current Probe  AP015
    500A, 2 MHz Current Probe  CP500
    150A, 10 MHz Current Probe   CP150
    15A, 50 MHz Current Probe   CP015
    100 MHz Differential Amplifier DA1855A
    Floppy Drive (External USB) WR6-FLPY
    Rackmount, 6U height WR6-RACK
    Mini Keyboard WR6-KBD
    Soft Shell Carrying Case WR6-SOFT
    Hard Shell Transit Case WR6-HARD
    Accessory Pouch WR6-POUCH
    Oscilloscope Cart OC1021
    Oscilloscope Cart with additional shelf and drawer OC1024
    Operators Manual Printed Hard Copy WR6-OM-E
    5-Year NIST Calibration and Warranty WR6-T5
    ?
    Warranty & Calibration
    A variety of extended warranty, certification, and calibration services are available.
    Contact LeCroy Sales and Service for details.